The effect of the hysteresis band on power management strategies in a stand-alone power system

Elmasides, Costas/ Papadopoulou, Simira/ Stergiopoulos, Fotis/ Seferlis, Panos/ Voutetakis, Spyros/ Ipsakis, Dimitris/ Ιψάκης, Δημήτρης/ Βουτετάκης, Σπύρος/ Σεφερλής, Πάνος/ Στεργιόπουλος, Φώτης/ Παπαδοπούλου, Σημίρα/ Ελμασίδης, Κωνσταντίνος


Institution and School/Department of submitter: ΤΕΙ Θεσσαλονίκης
Keywords: State Of Charge;Hysteresis Band;Power Management Strategies;Hydrogen Production;Stand-alone Power System;Renewable Energy Sources
Issue Date: 23-Aug-2008
Publisher: Elsevier
Citation: Ischia. 10th Conference on Process Integration, Modelling and Optimisation for Energy Saving and Pollution Reduction. (2007). The effect of the hysteresis band on power management strategies in a stand-alone power system. Elsevier (1537-1550)
Conference on Process Integration, Modelling and Optimisation for Energy Saving and Pollution Reduction, Ischia, 2007
Abstract: A stand-alone power system that consists of a photovoltaic array and wind generators for the exploitation of renewable energy sources (RES), and that is capable of storing excessive energy in the form of hydrogen via water electrolysis for subsequent use in a polymer electrolyte membrane (PEM) fuel cell is currently being installed at Neo Olvio of Xanthi in Greece. The performance of two power management strategies (PMSs) that utilize a hysteresis band in the operation of the integrated system over a typical 4-month period is assessed. The state-of-charge (SOC) level of the accumulator is the main parameter that governs the operation of the electrolyzer and the fuel cell. The introduction of a hysteresis band in the boundary limits of the SOC of the accumulator provides larger flexibility in the operation of the electrolyzer, the fuel cell, and the accumulator. In this way, the units can be protected from heavy and unnecessary utilization or irregular operation (reduction of frequent start-ups and shut-downs). The simulated results for the implemented PMSs revealed important information about the reliability of the load satisfaction, the total operation time that each subsystem undergoes, as well as about the hydrogen inventory in the integrated system. The study also identified the effect of variation of hysteresis band size on the system performance as an important feature for the development of an integrated control strategy.
Description: Δημοσιεύσεις μελών--ΣΤΕΦ--Τμήμα Αυτοματισμού, 2015
URI: http://195.251.240.227/jspui/handle/123456789/10016
ISSN: 0360-5442
Other Identifiers: doi:10.1016/j.energy.2008.07.012
http://www.sciencedirect.com/science/article/pii/S0360544208001734
Item type: other
Submission Date: 2018-02-28T16:11:14Z
Item language: el
Item access scheme: free
Institution and School/Department of submitter: ΤΕΙ Θεσσαλονίκης
Appears in Collections:Δημοσιεύσεις σε Περιοδικά

Files in This Item:
There are no files associated with this item.



 Please use this identifier to cite or link to this item:
http://195.251.240.227/jspui/handle/123456789/10016
  This item is a favorite for 0 people.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.