A Unified Procedure for Fault Detection of Analogue and Mixed-mode Circuits Using Magnitude and Phase Components of the Power Supply Current Spectrum
Papakostas, Dimitrios/ Hatzopoulos, Alkiviadis/ Παπακώστας, Δημήτριος/ Χατζόπουλος, Αλκιβιάδης
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Papakostas, Dimitrios | el |
dc.contributor.author | Hatzopoulos, Alkiviadis | el |
dc.contributor.editor | Παπακώστας, Δημήτριος | el |
dc.contributor.editor | Χατζόπουλος, Αλκιβιάδης | el |
dc.date.accessioned | 2015-07-03T10:24:59Z | el |
dc.date.accessioned | 2018-02-28T16:16:44Z | - |
dc.date.available | 2015-07-03T10:24:59Z | el |
dc.date.available | 2018-02-28T16:16:44Z | - |
dc.date.issued | 2008-11 | el |
dc.identifier | 10.1109/TIM.2008.924932 | el |
dc.identifier.citation | Journal: IEEE Transactions on Instrumentation and Measurement, vol.57, no.11, 2008 | el |
dc.identifier.citation | Papakostas, D. and Hatzopoulos, A. (2008). A Unified Procedure for Fault Detection of Analogue and Mixed-mode Circuits Using Magnitude and Phase Components of the Power Supply Current Spectrum. IEEE Transactions on Instrumentation and Measurement [online]. 57(11), pp.2589-2595. Διαθέσιμο σε: http://ieeexplore.ieee.org/xpl/login.jsp?tp=&arnumber=4534852&url=http%3A%2F%2Fieeexplore.ieee.org%2Fiel5%2F19%2F4647995%2F04534852.pdf%3Farnumber%3D4534852 [Ανακτήθηκε 19 Ιουλίου 2015] | el |
dc.identifier.issn | 0018-9456 | el |
dc.identifier.uri | http://195.251.240.227/jspui/handle/123456789/10045 | - |
dc.description | Δημοσιεύσεις μελών--ΣΤΕΦ--Τμήμα Ηλεκτρονικών Μηχανικών,2008 | el |
dc.description.abstract | A method using the power supply current for fault detection in analog and mixed-mode circuits is presented. A new unified fault detection procedure is introduced, and its fault detection capability is estimated. The procedure combines the rms value and the magnitude and phase components of the power supply current. Certain required discrimination factors are defined, and their values are adjusted to include circuit parameter deviations and matching dependencies for the efficient application of the method. Representative results from the simulation of an operational amplifier (opamp) and a flash analog-to-digital converter circuit are given, showing the effectiveness of the proposed method. | el |
dc.language.iso | en | el |
dc.publisher | IEEE | el |
dc.rights | Το τεκμήριο πιθανώς υπόκειται σε σχετική με τα Πνευματικά Δικαιώματα νομοθεσία | el |
dc.rights | This item is probably protected by Copyright Legislation | el |
dc.source.uri | http://ieee-ims.org/publications/transactions-tim | el |
dc.subject | Mixed analogue-digital integrated circuits | el |
dc.subject | Integrated circuit testing | el |
dc.subject | Fault diagnosis | el |
dc.subject | Analogue-digital conversion | el |
dc.subject | Power supply circuits | el |
dc.subject | Operational amplifiers | el |
dc.title | A Unified Procedure for Fault Detection of Analogue and Mixed-mode Circuits Using Magnitude and Phase Components of the Power Supply Current Spectrum | el |
dc.type | Article | el |
heal.type | other | el |
heal.type.en | Other | en |
heal.dateAvailable | 2018-02-28T16:17:44Z | - |
heal.language | el | el |
heal.access | free | el |
heal.recordProvider | ΤΕΙ Θεσσαλονίκης | el |
heal.fullTextAvailability | false | el |
heal.type.el | Άλλο | el |
Appears in Collections: | Δημοσιεύσεις σε Περιοδικά |
Files in This Item:
There are no files associated with this item.
Please use this identifier to cite or link to this item:
This item is a favorite for 0 people.
http://195.251.240.227/jspui/handle/123456789/10045
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.